2022-08-02 21:33:24 +02:00
---
manufacturer : ZTE
model : CICK
comments : The power card PRWG card uses– 48 V DC power and provides power supply to each card. The system supports two power cards. When the input voltage
of two power supplies is equal, the two PRWG cards work in load-balance mode.
console-ports :
- name : CLKI1 {module}
2023-01-21 01:17:02 +01:00
comments : The first BITS clock input interface, 75ohm
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : CLKI2 {module}
2023-01-21 01:17:02 +01:00
comments : The second BITS clock input interface, 75ohm
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : CLKO/1PPSO {module}
2023-01-21 01:17:02 +01:00
comments : BITS/1PPS+TOD clock output interface, 75ohm
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : CLKI1/TIMI1 {module}
2023-01-21 01:17:02 +01:00
comments : The first BITS/1PPS+TOD clock input interface, 120ohm
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : CLKI2/TIMI2 {module}
2023-01-21 01:17:02 +01:00
comments : The second BITS/1PPS+TOD clock input interface, 120ohm
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : CLKO/TIMO {module}
2023-01-21 01:17:02 +01:00
comments : BITS/1PPS+TOD clock output interface, 120ohm
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : ETH {module}
2023-01-21 01:17:02 +01:00
comments : Out-of-band maintenance network interface
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : COM {module}
2023-01-21 01:17:02 +01:00
comments : Public serial port
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : TEM {module}
2023-01-21 01:17:02 +01:00
comments : Temperature sensor interface
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : HUM
2023-01-21 01:17:02 +01:00
comments : Humid sensor interface
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : SMO {module}
2023-01-21 01:17:02 +01:00
comments : Smog sensor interface
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : LIQ {module}
2023-01-21 01:17:02 +01:00
comments : Liquid sensor interface
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : DOR {module}
2023-01-21 01:17:02 +01:00
comments : Entrance control sensor interface
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : DIN {module}
2023-01-21 01:17:02 +01:00
comments : Digit input interface, four channels
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true
- name : DOT {module}
2023-01-21 01:17:02 +01:00
comments : Digit input interface, four channels
2022-08-02 21:33:24 +02:00
type : rj-45
mgmt_only : true