mirror of
https://github.com/netbox-community/devicetype-library.git
synced 2025-01-31 18:49:26 +01:00
Updated Juniper EX92xx (#2585)
* Update EX9204.yaml Converted to module-bays * Create EX908.yaml * Update and rename EX908.yaml to EX9208.yaml * Update EX9214.yaml * Update EX9208.yaml fixed issue * Update IMS-GXL.yml Remove non-ASCII character * Fixed pre-commit issues
This commit is contained in:
parent
11a6d2b8be
commit
5100265924
@ -4,17 +4,21 @@ model: EX9204
|
||||
slug: juniper-ex9204
|
||||
u_height: 5
|
||||
is_full_depth: true
|
||||
subdevice_role: parent
|
||||
comments: '[Juniper EX9204 Data Sheet](https://www.juniper.net/us/en/local/pdf/datasheets/1000432-en.pdf)'
|
||||
console-ports:
|
||||
- name: Console-RE0
|
||||
type: rj-45
|
||||
power-ports:
|
||||
module-bays:
|
||||
- name: SF0
|
||||
position: '0'
|
||||
- name: SF1/LC0
|
||||
position: 1|0
|
||||
- name: LC1
|
||||
position: '1'
|
||||
- name: LC2
|
||||
position: '2'
|
||||
- name: PSU0
|
||||
type: iec-60320-c20
|
||||
position: '0'
|
||||
- name: PSU1
|
||||
type: iec-60320-c20
|
||||
position: '1'
|
||||
- name: PSU2
|
||||
type: iec-60320-c20
|
||||
position: '2'
|
||||
- name: PSU3
|
||||
type: iec-60320-c20
|
||||
positions: '3'
|
||||
|
35
device-types/Juniper/EX9208.yaml
Normal file
35
device-types/Juniper/EX9208.yaml
Normal file
@ -0,0 +1,35 @@
|
||||
---
|
||||
manufacturer: Juniper
|
||||
model: EX9208
|
||||
slug: juniper-ex9208
|
||||
u_height: 8
|
||||
weight: 30
|
||||
weight_unit: kg
|
||||
airflow: right-to-left
|
||||
is_full_depth: true
|
||||
comments: '[Juniper EX9208 System Overview](https://www.juniper.net/documentation/us/en/hardware/ex9208/topics/topic-map/ex9208-system-overview.html)'
|
||||
module-bays:
|
||||
- name: SF0
|
||||
position: '0'
|
||||
- name: SF1
|
||||
position: '1'
|
||||
- name: LC0
|
||||
position: '0'
|
||||
- name: LC1
|
||||
position: '1'
|
||||
- name: LC2
|
||||
position: '2'
|
||||
- name: LC3
|
||||
position: '3'
|
||||
- name: LC4
|
||||
position: '4'
|
||||
- name: LC5
|
||||
position: '5'
|
||||
- name: PSU0
|
||||
position: '0'
|
||||
- name: PSU1
|
||||
position: '1'
|
||||
- name: PSU2
|
||||
position: '2'
|
||||
- name: PSU3
|
||||
positions: '3'
|
@ -3,20 +3,45 @@ manufacturer: Juniper
|
||||
model: EX9214
|
||||
slug: juniper-ex9214
|
||||
u_height: 16
|
||||
weight: 68.04
|
||||
weight_unit: kg
|
||||
airflow: front-to-rear
|
||||
is_full_depth: true
|
||||
subdevice_role: parent
|
||||
comments: '[Juniper EX9214 Data Sheet](https://www.juniper.net/us/en/local/pdf/datasheets/1000432-en.pdf)'
|
||||
console-ports:
|
||||
- name: Console-RE0
|
||||
type: rj-45
|
||||
- name: Console-RE1
|
||||
type: rj-45
|
||||
power-ports:
|
||||
module-bays:
|
||||
- name: SF0
|
||||
position: '0'
|
||||
- name: SF1
|
||||
position: '1'
|
||||
- name: LC0
|
||||
position: '0'
|
||||
- name: LC1
|
||||
position: '1'
|
||||
- name: LC2
|
||||
position: '2'
|
||||
- name: LC3
|
||||
position: '3'
|
||||
- name: LC4
|
||||
position: '4'
|
||||
- name: LC5
|
||||
position: '5'
|
||||
- name: SF2/LC6
|
||||
position: 2/6
|
||||
- name: LC7
|
||||
position: '7'
|
||||
- name: LC8
|
||||
position: '8'
|
||||
- name: LC9
|
||||
position: '9'
|
||||
- name: LC10
|
||||
position: '10'
|
||||
- name: LC11
|
||||
position: '11'
|
||||
- name: PSU0
|
||||
type: iec-60320-c20
|
||||
position: '0'
|
||||
- name: PSU1
|
||||
type: iec-60320-c20
|
||||
position: '1'
|
||||
- name: PSU2
|
||||
type: iec-60320-c20
|
||||
position: '2'
|
||||
- name: PSU3
|
||||
type: iec-60320-c20
|
||||
positions: '3'
|
||||
|
@ -3,13 +3,11 @@ manufacturer: Schweitzer Engineering Laboratories
|
||||
model: SEL-2243 Power Coupler
|
||||
description: Every SEL Axion node requires at least one SEL-2243 Power Coupler module. The SEL-2243 serves two purposes in an Axion system. It is the power
|
||||
supply for all modules installed in the node, and; It provides two dedicated EtherCAT ports so that mutiple Axion nodes can operate together.
|
||||
|
||||
interfaces:
|
||||
- name: Eth01
|
||||
type: 100base-tx
|
||||
- name: Eth02
|
||||
type: 100base-tx
|
||||
|
||||
power-ports:
|
||||
- name: dc power terminal
|
||||
type: dc-terminal
|
||||
|
@ -3,7 +3,6 @@ manufacturer: Schweitzer Engineering Laboratories
|
||||
model: SEL-2244-5 Fast High-Current Digital Output Module
|
||||
description: The SEL-2244-5 module includes ten control outputs with LED indication that have high current tripping capacity (10 A) and fast output rise
|
||||
time (<16 at 125 V). Up to nine modules may be used in a node
|
||||
|
||||
interfaces:
|
||||
- name: Digital-output terminal
|
||||
type: other
|
||||
|
@ -3,7 +3,6 @@ manufacturer: Schweitzer Engineering Laboratories
|
||||
model: SEL-2245-2 DC Analog Input Module
|
||||
description: The SEL-2245-2 module includes 16 inputs that are software-selectable for input ranges of 20 mA, 2 mA, or +10 V. Up to 9 modules may be used
|
||||
in a node, and a maximum of 16 analog modules may be used in one Axion system.
|
||||
|
||||
interfaces:
|
||||
- name: Analog-input terminal
|
||||
type: other
|
||||
|