* add various cisco module types
* add missing schema
* correct file name and part number for C4KX-PWR-750DC-R.yaml
* correct part number for C4KX-PWR-750DC-R.yaml and C4KX-PWR-750WAC-R.yaml
---------
Co-authored-by: Abu Rehan <abreh@equinor.com>
* Synology RS2416RP+
* Adding of bay for PSU & template for installed PSU
* Change name of power-port
* Power port name modifiaction
---------
Co-authored-by: Placeholder Author <placeholder@author.com>
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>
* Regenerate master slug list after successful PR merge
* * Add Nokia IXR-H2 and IXR-H4 devices with images
* Fix power port type for DC
* H4 only supports F2B airflow, so we can specify that
---------
Co-authored-by: NetBox-Bot <info@netboxlabs.com>
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>
* Add base metadata and interfaces
* Add module bays
* Remove ACX5048
* Add ACX5048-AC
* Amend model and slug for AC variant
* Add management interfaces
* Add part number
* Add ACX5048 DC variant
* Add 650W AC PSU module
* Add ACX5048/QFX5100 AFO fan module
* Add airflow attribute
---------
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>
* wip
* more details
* remove header comments
* fix module ports
* use description instead of comment + caps part num
* reorg fields, add missing info, remove description
* fix delta models
* fix 1000base-t
* remove slug from module
* remove airflow, depth, height from module
* change PSUs from devices to modules
* add detailed info for liteon psu
* remove trailing spaces
* new line at end of file
* use mgmt instead of console
---------
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>
* Create WAN devices
* Add mgmt interfaces
* Remove unused parameter
* Linter
* Update PSU type to match schema
* Address feedback re weight, airflow, and PSUs
* Fix linting for new files
* Adding Fortinet FG-800D and FG-3700D
* Adding Images for Fortinet FG-800D and FG-3700D
* Removing descriptions and renaming images to follow standard
* Running pre-commit tests and linting on a Linux machine
* Extracting Power Supply spec into Modules
* Changing integer to string in Module Position
* Running linter on a linux machine
---------
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>
* Fix incorrect part number for HPE Aruba 2920-24G-PoE+
* Fix power figures
* Added Aruba 2920-48G-PoE+-740W model
* Add weight info
* Added module bays
* Added HPE 2920 series modules
* Added missing comments field
* Fix trailing spaces
* Fix part number
* Add missing quotes
* Fix part number
* Add XPS port and replace PS1 port with power supply module slot
* Add HPE J9737A, J9738A, J9739A, power supplies
* Add position number to 2920 series PSU module bay
* Add Aruba 640 Redundant/External Power Supply Shelf
* Add missing quotes around position number
* Make PS1 modular and add XPS port
* Add quotes around position number
* Typo fixes
* Fix quotes
---------
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>
* Regenerate master slug list after successful PR merge
* Update DCS-7280CR3-32D4 with PSU modules
* Fix correct port layout for DCS-7280CR3-32D4
* Adding Arista PSUs
* Adding comment with url to datasheet
* Adding more devices from 7280CR3 family
* Fix my lint fail
* Fixing my second lint fail
* Fixing another silly fail!
* Fixes after review
* removing known-slugs
* Fix SKUs to align with airflow instead of generic
* fixing picke file
* another picke fix
---------
Co-authored-by: NetBox-Bot <info@netboxlabs.com>
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>
* Added test functionality to use original all files testing. Fixed JPSU-920-AC-AFO issue from Issue#1514
* Fixed JPSU issue
* Fixing file format issue
* fixing file we altered by accident
* Juniper QFX5120 and QFX5130 Family
* adding power supplies for QFX5120 and QFX5130 switches
* fix a typo
---------
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>
* Regenerate master slug list after successful PR merge
* Juniper QFX10002 Family
* known-slugs.pickle stuff..
---------
Co-authored-by: NetBox-Bot <info@netboxlabs.com>
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>
* Adding ACX7100-32C (Juniper)
* Adding EX4400 Series Switches (Juniper)
* align slug to start with vendor-name
* adding module types
* remove airflow from modules and adding weight to ACX7100-32C
* create device types for all ACX7100 models
* fix position
* adding AFI, AFO and AC/DC models for EX4400 series
* fix slug
* add part_number to all devices
* fix typo in module name
---------
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>
* Adding C300 and C400 models
* Add Certa UPS models and battery packs
* CNMC management card
* New line fix
---------
Co-authored-by: Daniel W. Anner <daniel.anner@danstechsupport.com>