mirror of
https://github.com/netbox-community/devicetype-library.git
synced 2024-11-28 19:34:18 +01:00
961b0b2a62
* remove (r) * remove (tm) * replace all dashes with ascii - * replace double quotes * Replace another type of dash * replace multiply by x * replace a third type of dash * remaining substitutions by hand * fix line lenght --------- Co-authored-by: Giotta Simon <simon.giotta@ruag.ch> Co-authored-by: Harry <Harry@cadby.co.uk>
67 lines
1.9 KiB
YAML
67 lines
1.9 KiB
YAML
---
|
|
manufacturer: ZTE
|
|
model: CICK
|
|
comments: The power card PRWG card uses-48 V DC power and provides power supply to each card. The system supports two power cards. When the input voltage
|
|
of two power supplies is equal, the two PRWG cards work in load-balance mode.
|
|
console-ports:
|
|
- name: CLKI1 {module}
|
|
comments: The first BITS clock input interface, 75ohm
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: CLKI2 {module}
|
|
comments: The second BITS clock input interface, 75ohm
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: CLKO/1PPSO {module}
|
|
comments: BITS/1PPS+TOD clock output interface, 75ohm
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: CLKI1/TIMI1 {module}
|
|
comments: The first BITS/1PPS+TOD clock input interface, 120ohm
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: CLKI2/TIMI2 {module}
|
|
comments: The second BITS/1PPS+TOD clock input interface, 120ohm
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: CLKO/TIMO {module}
|
|
comments: BITS/1PPS+TOD clock output interface, 120ohm
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: ETH {module}
|
|
comments: Out-of-band maintenance network interface
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: COM {module}
|
|
comments: Public serial port
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: TEM {module}
|
|
comments: Temperature sensor interface
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: HUM
|
|
comments: Humid sensor interface
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: SMO {module}
|
|
comments: Smog sensor interface
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: LIQ {module}
|
|
comments: Liquid sensor interface
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: DOR {module}
|
|
comments: Entrance control sensor interface
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: DIN {module}
|
|
comments: Digit input interface, four channels
|
|
type: rj-45
|
|
mgmt_only: true
|
|
- name: DOT {module}
|
|
comments: Digit input interface, four channels
|
|
type: rj-45
|
|
mgmt_only: true
|