mirror of
https://github.com/netbox-community/devicetype-library.git
synced 2024-12-28 09:59:39 +01:00
b978c8376d
* Add ZTE vendor and ZXA10 F8x2 GPON MTU series * Add generic SC-24-double-port Fiber Patch Panel * fix numbers * Add some Cisco-Meraki APs * fix wrong added .pre-commit-config.yaml * Add ZTE ZXA10 C300 * Added SC-24-port_fiber_patch_panel * Add basic zte c300 modules: CICK,PRWH and HUVQ * add ZTE modules * Rename GPON interface * Add Supermicro model SYS-1019P-WTR * Fix typo in com ports type * Add M4300-12X12F * Revert to module * Revision done * Fix little typos * Remove empty comments * Remove empty comments * Fix type * Fix type * Fix rear_port_position * Fix typo * Modify type * Remove USB and VGA * Remove USB and VGA
67 lines
2.0 KiB
YAML
67 lines
2.0 KiB
YAML
---
|
||
manufacturer: ZTE
|
||
model: CICK
|
||
comments: The power card PRWG card uses–48 V DC power and provides power supply to each card. The system supports two power cards. When the input voltage
|
||
of two power supplies is equal, the two PRWG cards work in load-balance mode.
|
||
console-ports:
|
||
- name: CLKI1 {module}
|
||
description: The first BITS clock input interface, 75ohm
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: CLKI2 {module}
|
||
description: The second BITS clock input interface, 75ohm
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: CLKO/1PPSO {module}
|
||
description: BITS/1PPS+TOD clock output interface, 75ohm
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: CLKI1/TIMI1 {module}
|
||
description: The first BITS/1PPS+TOD clock input interface, 120ohm
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: CLKI2/TIMI2 {module}
|
||
description: The second BITS/1PPS+TOD clock input interface, 120ohm
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: CLKO/TIMO {module}
|
||
description: BITS/1PPS+TOD clock output interface, 120ohm
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: ETH {module}
|
||
description: Out-of-band maintenance network interface
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: COM {module}
|
||
description: Public serial port
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: TEM {module}
|
||
description: Temperature sensor interface
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: HUM
|
||
description: Humid sensor interface
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: SMO {module}
|
||
description: Smog sensor interface
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: LIQ {module}
|
||
description: Liquid sensor interface
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: DOR {module}
|
||
description: Entrance control sensor interface
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: DIN {module}
|
||
description: Digit input interface, four channels
|
||
type: rj-45
|
||
mgmt_only: true
|
||
- name: DOT {module}
|
||
description: Digit input interface, four channels
|
||
type: rj-45
|
||
mgmt_only: true
|