This patch enables rclone to be used as a library from within restic
- exposes NewServer
- exposes Server
- implements http.RoundTripper
Co-authored-by: Jack Deng <jackdeng@gmail.com>
- Use cache to store package versions
- Update actions/setup-go to v2
- Add go1.15-rc1 build
- Make seperate build step
- stop downloading code into special path
- leave adding ~/go/bin to PATH to sction/setup-go
- remove docker build from xgo as we are building rclone anyway
- remove modules setting since it is now always on
- use ./... instead of listing files in tests
go1.15 introduced a stricter policy for what you can convert with
`string()` and now `go vet` warns if you try to do `string(int)`.
See: https://github.com/golang/go/issues/32479
When we run MKCOL on 4shared on a directory that already exists, this
returns a 409/Conflict error. However this error code usually means
that the intermediate collections need creating.
The actual error code to return when trying to create a directory that
already exists isn't specified in the RFC, only that an error MUST be
returned and there are already 3 statuses checked in the code.
However using 409 makes rclone's usual strategy for making directories
fail and return the 409 error.
This patch tries the MKCOL and if it returns an unrecognised error
code, then calls PROPFIND on the directory to discover whether the
directory really exists or not.
This should also cover other WebDAV servers returning other error
messages we haven't accounted for in the code yet.
Before this change when reading directories we would use the directory
handle and the Readdir(-1) call on the directory handle. This worked
fine for the first read, but if the directory was read again on the
same handle Readdir(-1) returns nothing (as per its design).
It turns out that macOS leaves the directory handle open and just
re-reads the data from it, so this problem causes directories to start
out full then subsequently appear empty.
macOS/OSXFUSE is passing an offset of 0 to the Readdir call telling
rclone to seek in the directory, but we've told FUSE that we can't
seek by always returning ofst=0 in the fill function.
This fix works around the problem by reading the directory from the
path each time, ignoring the actual handle. This should be no less
efficient.
We will return an ESPIPE if offset is ever non 0.
There are possible corner cases reading deleted directories which this
ignores.
Before this change the cache backend contained its own routines for
mounting testing on that mount.
These tests are never run on the CI and cause a maintenance burden.
This commit removes the tests.
If the parameter being passed is an object then it can be passed as a
JSON string rather than using the `--json` flag which simplifies the
command line.
rclone rc operations/list fs=/tmp remote=test opt='{"showHash": true}'
Rather than
rclone rc operations/list --json '{"fs": "/tmp", "remote": "test", "opt": {"showHash": true}}'
This uses the refactored goftp library which doesn't include the minio
driver. This reduces the binary size by 1.5MB
See: https://gitea.com/goftp/server/pulls/120
Before this fix we took the directory lock to read the ModTime of the
directory. This was causing locking on directories which were being
re-read from the backend.
This commit gives the modtime its own lock so it can be read even when
the directory is being updated.
See: https://forum.rclone.org/t/high-cpu-load-with-rclone-mount/17604
Before this change files that were in the cache and renamed with
--vfs-cache-mode minimal weren't renamed at all.
This fixes the problem and adds tests for all the different
combinations of cache modes and in and out of the cache.
In this commit (released in v1.52.0)
6ca7198f mount: fix disappearing cwd problem
SetSys was introduced to cache node lookups.
Unfortunately taking the vfs.(*Dir) lock in SetSys causes any FUSE
operations on a directory to pile up behind slow directory listings.
In some situations this leads to very high load.
This commit fixes it by using atomic operations to read and write the
Sys value make it independent of the lock.
See: https://forum.rclone.org/t/high-cpu-load-with-rclone-mount/17604
See: #4104
The documentation contains an embedded datetime which do not read
SOURCE_DATE_EPOCH. This makes the documentation unreproducible when
distribution tries to recreate previous build of the package.
This patch ensures we attempt to read the environment variable before
default to the current build time.
Signed-off-by: Morten Linderud <morten@linderud.pw>
Removed comma from the end of the Azure AD Applications List Blade URL since it was not resolving and customers were opening up support tickets with the Microsoft Azure AD team.
Previous to this fix if Region was not set and Endpoint was not set
then we set the endpoint to "https://s3.amazonaws.com/".
This is unecessary because if the Region alone isn't set then we set
it to "us-east-1" which has the same endpoint.
Having the endpoint set breaks the bucket region auto detection with
the error "Failed to update region for bucket: can't set region to
"xxx" as endpoint is set".
This fix removes that check.
At some point Purge stopped deleting directory markers. We don't have
an integration test for this so it went unnoticed.
This patch fixes the problem but doesn't introduce an integration test
as we don't have a framework for making directory markers yet.
Before this change, large objects which had had their contents deleted
would return "Object not found" and break the listing.
This change makes these objects appear as 0 sized entities so they can
be listed and deleted.