Update haos-vm.sh

This commit is contained in:
tteckster 2022-04-16 20:24:39 -04:00 committed by GitHub
parent d5891a8e0f
commit 320a9c2b27
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23

View File

@ -1,6 +1,5 @@
#!/usr/bin/env bash
NEXTID=$(pvesh get /cluster/nextid)
INTEGER='^[0-9]+$'
YW=`echo "\033[33m"`
BL=`echo "\033[36m"`
RD=`echo "\033[01;31m"`
@ -29,8 +28,7 @@ echo -e "${BL}
| |__| | / \ | | | | (___
| __ | / /\ \| | | |\___ \
| | | |/ ____ \ |__| |____) |
|_| |_/_/ \_\____/|_____/
|_| |_/_/ ${CL}${YW}v3${CL}${BL} \_\____/|_____/
${CL}"
}
header_info
@ -48,41 +46,47 @@ function default_settings() {
clear
header_info
echo -e "${BL}Using Default Settings${CL}"
echo -e "${DGN}Using ID ${BGN}$NEXTID${CL}"
VM_ID=$NEXTID
echo -e "${DGN}Using Disk Size ${BGN}32GB${CL}"
DISK_SIZE=16
echo -e "${DGN}Using VM ID ${BGN}$NEXTID${CL}"
VMID=$NEXTID
echo -e "${DGN}Using VM Name ${BGN}haos${CL}"
VM_NAME=haos
echo -e "${DGN}Using ${BGN}2vCPU${CL}"
CORE_COUNT="2"
echo -e "${DGN}Using ${BGN}4096MiB${CL}${GN} RAM${CL}"
echo -e "${DGN}Using ${BGN}4096MiB${CL}"
RAM_SIZE="4096"
echo -e "${DGN}Start VM when completed ${BGN}yes${CL}"
START_VM="yes"
}
function advanced_settings() {
clear
header_info
echo -e "${RD}Using Advanced Settings${CL}"
echo -e "${YW}Enter the VM ID, or Press [ENTER] to automatically generate (${NEXTID}) "
read VM_ID
if [ -z $VM_ID ]; then VM_ID=$NEXTID; fi;
echo -en "${DGN}Set VM ID To ${BL}$VM_ID${CL}"
read VMID
if [ -z $VMID ]; then VMID=$NEXTID; fi;
echo -en "${DGN}Set VM ID To ${BL}$VMID${CL}"
echo -e " ${CM}${CL} \r"
sleep 1
clear
header_info
echo -e "${RD}Using Advanced Settings${CL}"
echo -e "${DGN}Using ID ${BGN}$VM_ID${CL}"
echo -e "${YW}Enter a Disk Size, or Press [ENTER] for Default: 32Gb "
read DISK_SIZE
if [ -z $DISK_SIZE ]; then DISK_SIZE=32; fi;
if ! [[ $DISK_SIZE =~ $INTEGER ]] ; then echo "ERROR! DISK SIZE MUST HAVE INTEGER NUMBER!"; exit; fi;
echo -en "${DGN}Set Disk Size To ${BL}$DISK_SIZE${CL}"
echo -e "${DGN}Using VM ID ${BGN}$VMID${CL}"
echo -e "${YW}Enter VM Name (no-spaces), or Press [ENTER] for Default: hoas "
read VMNAME
if [ -z $VMNAME ]; then
VM_NAME=haos
else
VM_NAME=$(echo ${VMNAME,,} | tr -d ' ')
fi
echo -en "${DGN}Set CT Name To ${BL}$VM_NAME${CL}"
echo -e " ${CM}${CL} \r"
sleep 1
clear
header_info
echo -e "${RD}Using Advanced Settings${CL}"
echo -e "${DGN}Using ID ${BGN}$VM_ID${CL}"
echo -e "${DGN}Using Disk Size ${BGN}${DISK_SIZE}GB${CL}"
echo -e "${DGN}Using VM ID ${BGN}$VMID${CL}"
echo -e "${DGN}Using VM Name ${BGN}$VM_NAME${CL}"
echo -e "${YW}Allocate CPU cores, or Press [ENTER] for Default: 2 "
read CORE_COUNT
if [ -z $CORE_COUNT ]; then CORE_COUNT="2"; fi;
@ -92,8 +96,8 @@ sleep 1
clear
header_info
echo -e "${RD}Using Advanced Settings${CL}"
echo -e "${DGN}Using ID ${BGN}$VM_ID${CL}"
echo -e "${DGN}Using Disk Size ${BGN}${DISK_SIZE}GB${CL}"
echo -e "${DGN}Using VM ID ${BGN}$VMID${CL}"
echo -e "${DGN}Using VM Name ${BGN}$VM_NAME${CL}"
echo -e "${DGN}Using ${BGN}${CORE_COUNT}vCPU${CL}"
echo -e "${YW}Allocate RAM in MiB, or Press [ENTER] for Default: 4096 "
read RAM_SIZE
@ -104,10 +108,26 @@ sleep 1
clear
header_info
echo -e "${RD}Using Advanced Settings${CL}"
echo -e "${DGN}Using ID ${BGN}$VM_ID${CL}"
echo -e "${DGN}Using Disk Size ${BGN}${DISK_SIZE}GB${CL}"
echo -e "${DGN}Using VM ID ${BGN}$VMID${CL}"
echo -e "${DGN}Using VM Name ${BGN}$VM_NAME${CL}"
echo -e "${DGN}Using ${BGN}${CORE_COUNT}vCPU${CL}"
echo -e "${DGN}Using ${BGN}${RAM_SIZE}MiB${CL}${DGN} RAM${CL}"
echo -e "${DGN}Using ${BGN}${RAM_SIZE}MiB${CL}"
echo -e "${YW}Start VM when completed, or Press [ENTER] for Default: yes "
read START_VM
if [ -z $START_VM ]; then START_VM="yes";
else
START_VM="no"; fi;
echo -en "${DGN}Starting VM when completed ${BL}$START_VM${CL}"
echo -e " ${CM}${CL} \n"
sleep 1
clear
header_info
echo -e "${RD}Using Advanced Settings${CL}"
echo -e "${DGN}Using VM ID ${BGN}$VMID${CL}"
echo -e "${DGN}Using VM Name ${BGN}$VM_NAME${CL}"
echo -e "${DGN}Using ${BGN}${CORE_COUNT}vCPU${CL}"
echo -e "${DGN}Using ${BGN}${RAM_SIZE}MiB${CL}"
echo -e "${DGN}Start VM when completed ${BGN}$START_VM${CL}"
read -p "Are these settings correct(y/n)? " -n 1 -r
echo
@ -142,7 +162,7 @@ function error_exit() {
local REASON="\e[97m${1:-$DEFAULT}\e[39m"
local FLAG="\e[91m[ERROR] \e[93m$EXIT@$LINE"
msg "$FLAG $REASON"
[ ! -z ${VM_ID-} ] && cleanup_vm_id
[ ! -z ${VMID-} ] && cleanup_vmid
exit $EXIT
}
function warn() {
@ -159,12 +179,12 @@ function msg() {
local TEXT="$1"
echo -e "$TEXT"
}
function cleanup_vm_id() {
if $(qm status $VM_ID &>/dev/null); then
if [ "$(qm status $VM_ID | awk '{print $2}')" == "running" ]; then
qm stop $VM_ID
function cleanup_vmid() {
if $(qm status $VMID &>/dev/null); then
if [ "$(qm status $VMID | awk '{print $2}')" == "running" ]; then
qm stop $VMID
fi
qm destroy $VM_ID
qm destroy $VMID
fi
}
function cleanup() {
@ -198,7 +218,7 @@ else
done
fi
msg_ok "Using ${CL}${BL}$STORAGE${CL} ${GN}for Storage Location."
msg_ok "Virtual Machine ID is ${CL}${BL}$VM_ID${CL}."
msg_ok "Container ID is ${CL}${BL}$VMID${CL}."
msg_info "Getting URL for Latest Home Assistant Disk Image"
RELEASE_TYPE=qcow2
URL=$(cat<<EOF | python3
@ -225,7 +245,7 @@ msg_ok "${CL}${BL}${URL}${CL}"
wget -q --show-progress $URL
echo -en "\e[1A\e[0K"
FILE=$(basename $URL)
msg_ok "Downloaded ${RELEASE_TYPE} Disk Image"
msg_ok "Downloaded ${CL}${BL}${RELEASE_TYPE}${CL}${GN} Disk Image"
msg_info "Extracting Disk Image"
case $FILE in
*"gz") gunzip -f $FILE ;;
@ -237,26 +257,25 @@ STORAGE_TYPE=$(pvesm status -storage $STORAGE | awk 'NR>1 {print $2}')
case $STORAGE_TYPE in
btrfs|nfs|dir)
DISK_EXT=".qcow2"
DISK_REF="$VM_ID/"
DISK_REF="$VMID/"
IMPORT_OPT="-format qcow2"
esac
for i in {0,1}; do
disk="DISK$i"
eval DISK${i}=vm-${VM_ID}-disk-${i}${DISK_EXT:-}
eval DISK${i}=vm-${VMID}-disk-${i}${DISK_EXT:-}
eval DISK${i}_REF=${STORAGE}:${DISK_REF:-}${!disk}
done
msg_ok "Extracted Disk Image"
msg_info "Creating HAOS VM"
VM_NAME=$(sed -e "s/\_//g" -e "s/.${RELEASE_TYPE}.*$//" <<< $FILE)
qm create $VM_ID -agent 1 -bios ovmf -cores ${CORE_COUNT} -memory ${RAM_SIZE} -name $VM_NAME -net0 virtio,bridge=vmbr0 \
qm create $VMID -agent 1 -bios ovmf -cores $CORE_COUNT -memory $RAM_SIZE -name $VM_NAME -net0 virtio,bridge=vmbr0 \
-onboot 1 -ostype l26 -scsihw virtio-scsi-pci
pvesm alloc $STORAGE $VM_ID $DISK0 128 1>&/dev/null
qm importdisk $VM_ID ${FILE%.*} $STORAGE ${IMPORT_OPT:-} 1>&/dev/null
qm set $VM_ID \
pvesm alloc $STORAGE $VMID $DISK0 128 1>&/dev/null
qm importdisk $VMID ${FILE%.*} $STORAGE ${IMPORT_OPT:-} 1>&/dev/null
qm set $VMID \
-efidisk0 ${DISK0_REF},size=128K \
-scsi0 ${DISK1_REF},size=${DISK_SIZE}G >/dev/null
qm set $VM_ID \
-scsi0 ${DISK1_REF},size=32G >/dev/null
qm set $VMID \
-boot order=scsi0 >/dev/null
set +o errtrace
(
@ -265,8 +284,8 @@ msg_ok "Created HAOS VM ${CL}${BL}${VM_NAME}"
msg_info "Adding Serial Port and Configuring Console"
trap '
warn "Unable to configure serial port. VM is still functional."
if [ "$(qm config $VM_ID | sed -n ''/serial0/p'')" != "" ]; then
qm set $VM_ID --delete serial0 >/dev/null
if [ "$(qm config $VMID | sed -n ''/serial0/p'')" != "" ]; then
qm set $VMID --delete serial0 >/dev/null
fi
exit
' ERR
@ -289,10 +308,11 @@ msg_ok "Added Serial Port and Configured Console"
mkdir $TEMP_MOUNT
mount $DISK1_PART1_PATH $TEMP_MOUNT
sed -i 's/$/ console=ttyS0/' ${TEMP_MOUNT}/cmdline.txt
qm set $VM_ID -serial0 socket >/dev/null
qm set $VMID -serial0 socket >/dev/null
)
if [ "$START_VM" == "yes" ]; then
msg_info "Starting Home Assistant OS VM"
qm start $VM_ID
qm start $VMID
msg_ok "Started Home Assistant OS VM"
fi
msg_ok "Completed Successfully!\n"