Signal handling by the `atexit` package needs acceess to
`exitCodeUncategorizedError`. With this change all exit status values
are moved to a dedicated package so that they can be reused.
Signed-off-by: Michael Hanselmann <public@hansmi.ch>
Currently rclone check supports matching two file trees by sizes and hashes.
This change adds support for SUM files produced by GNU utilities like sha1sum.
Fixes#1005
Note: checksum by default checks, hashsum by default prints sums.
New flag is named "--checkfile" but carries hash name.
Summary of introduced command forms:
```
rclone check sums.sha1 remote:path --checkfile sha1
rclone checksum sha1 sums.sha1 remote:path
rclone hashsum sha1 remote:path --checkfile sums.sha1
rclone sha1sum remote:path --checkfile sums.sha1
rclone md5sum remote:path --checkfile sums.md5
```
Some environment variables didn’t behave like their corresponding
command line flags. The affected flags were --stats, --log-level,
--separator, --multi-tread-streams, --rc-addr, --rc-user and --rc-pass.
Example:
RCLONE_STATS='10s'
rclone check remote: remote: --progress
# Expected: rclone check remote: remote: --progress –-stats=10s
# Actual: rclone check remote: remote: --progress
Remote specific options set by environment variables was overruled by
less specific backend options set by environment variables. Example:
RCLONE_DRIVE_USE_TRASH='false'
RCLONE_CONFIG_MYDRIVE_USE_TRASH='true'
rclone deletefile myDrive:my-test-file
# Expected: my-test-file is recoverable in the trash folder
# Actual: my-test-file is permanently deleted (not recoverable)
Backend specific options set by environment variables was overruled by
general backend options set by environment variables. Example:
RCLONE_SKIP_LINKS='true'
RCLONE_LOCAL_SKIP_LINKS='false'
rclone lsd local:
# Expected result: Warnings when symlinks are skipped
# Actual result: No warnings when symlinks are skipped
# That is RCLONE_SKIP_LINKS takes precedence
The above issues have been fixed.
The debug logging (-vv) has been enhanced to show when flags are set by
environment variables.
The documentation has been enhanced with details on the precedence of
configuration options.
See pull request #5341 for more information.
- Unify all hash names as lowercase alphanumerics without punctuation.
- Legacy names continue to work but disappear from docs, they can be depreciated or dropped later.
- Make rclone hashsum print supported hash list in case of wrong spelling.
- Update documentation.
Fixes#5071Fixes#4841
This also factors the config questions into a state based mechanism so
a backend can be configured using the same dialog as rclone config but
remotely.
This is a very large change which turns the post Config function in
backends into a state based call and response system so that
alternative user interfaces can be added.
The existing config logic has been converted, but it is quite
complicated and folloup commits will likely be needed to fix it!
Follow up commits will add a command line and API based way of using
this configuration system.
Includes adding support for additional size input suffix Mi and MiB, treated equivalent to M.
Extends binary suffix output with letter i, e.g. Ki and Mi.
Centralizes creation of bit/byte unit strings.
Restructuring of config code in v1.55 resulted in config
file being loaded early at process startup. If configuration
file is encrypted this means user will need to supply the password,
even when running commands that does not use config.
This also lead to an issue where mount with --deamon failed to
decrypt the config file when it had to prompt user for passord.
Fixes#5236Fixes#5228
A new command `rclone config touch` which calls config.SaveConfig().
Useful during testing of configuration location things.
It will ensure the config file exists and test that it is writable.
Before this patch selfupdate detected ANY build with cmount tag as a build
having libFUSE capabilities. However, only dynamic builds really have it.
The official linux builds are static and have the cmount tag as of the time
of this writing. This results in inability to update official linux binaries.
This patch fixes that. The build can be fixed independently.
This patch modifies the output of `rclone version`.
The `os/arch` line is split into `os/type` and `os/arch`.
The `go version` line is now tagged as `go/version` for consistency.
Additionally the `go/linking` line tells whether the rclone
was linked as a static or dynamic executable.
The new `go/tags` line shows a space separated list of build tags.
The info about linking and build tags is also added to the output
of the `core/version` RC endpoint.
It was discovered `rclone mount` (but not `rclone cmount`) cached
directories after rename which it shouldn't have done.
This caused IO errors when trying to access files in renamed
directories on bucket based file systems.
This turned out to be the kernel caching the directories as basil/fuse
sets their expiry time to 60s for some reason.
This fix invalidates the relevant kernel cache entries in the for the
directories which fixes the problem.
Fixes: #4977
See: https://forum.rclone.org/t/after-a-directory-renmane-using-mv-files-are-not-visible-any-longer/22797
If you are using rclone a library you can decide to use the rclone
config file system or not by calling
configfile.LoadConfig(ctx)
If you don't you will need to set `config.Data` to an implementation
of `config.Storage`.
Other changes
- change interface of config.FileGet to remove unused default
- remove MustValue from config.Storage interface
- change GetValue to return string or bool like elsewhere in rclone
- implement a default config file system which panics with helpful error
- implement getWithDefault to replace the removed MustValue
- don't embed goconfig.ConfigFile so we can change the methods
Previously rclone set --daemon-timeout to 15m by default. However
osxfuse seems to be ignoring that value since it is above the maximum
value of 10m. This is conjecture since the source of osxfuse is no
longer available.
Setting the value to 10m seems to resolve the problem.
See: https://forum.rclone.org/t/rclone-mount-frequently-drops-when-using-plex/22352
This adds
-o modules=iconv,from_code=UTF-8,to_code=UTF-8-MAC
To the mount options if it isn't already present which fixes mounting
issues on macOS with accented characters in the finder.
Before this change, if one connection was authenticating this would
block any others from authenticating.
This was due to ssh.NewServerConn not being called in a go routine
after the Accept call.
This is fixed by running the ssh authentication in a go routine.
Thanks to @FiloSottile for advice on how to fix this.
See: https://github.com/golang/go/issues/43521
Implemented empty folder flag for ncdu browser interface. If there is
empty folder in the list the flag e is prepended before size. If there
is no empty folder this flag is ommited. It has the same behaviour as
original ncdu browser. (https://dev.yorhel.nl/ncdu/man)
When a directory cannot be walk-ed because of a permissions error
- or any error for that matter -, ncdu mode keeps track of the error
and highlights directories that could not be read.
Previously, the error would cause ncdu to abort.
Now, directories with unreadable sub-directories are displayed in yellow and
a message warns that the total may be underestimated.
Unreadable directories themselves are displayed in red along with the error message
Add --network-mode option to activate mounting as network drive without having to set volume prefix.
Add support for automatic drive letter assignment (not specific to network drive mounting).
Allow full network share unc path in --volname, which will also implicitely activate network drive mounting.
Allow full network share unc path as mountpoint, which will also implicitely activate network drive mounting, and the specified path will be used as volume prefix and the remote will be mounted on an automatically assigned drive letter instead.
This commit modifies the operations.hashSum function by adding an alternate code path. This code path is triggered by passing downloadFlag = True. When activated, rclone will download files from the remote and hash them locally. downloadFlag = False preserves the existing behavior of using the remote to retrieve the hash.
This commit modifies HashLister to support the new hashSum method as well as consolidating the roles of HashLister, HashListerBase64, Md5sum, and Sha1sum. The printing of hashes from the function defined in HashLister has been revised to work with --progress. There are light changes to operations.syncFprintf and cmd.startProgress for this.
The unit test operations_test.TestHashSums is modified to support this change and test the download functionality.
The command functions hashsum, md5sum, sha1sum, and dbhashsum are modified to support this change. A download flag has been added and an output-file flag has been added. The output-file flag writes hashes to a file instead of stdout to avoid the need to redirect stdout.
When using `--baseurl` before this patch, if a request was made to the
base URL without a trailing / then rclone would return a 404 error.
Unfortunately GVFS / Nautilus makes the request without the /
regardless of what the user put in.
This patch redirects the request to the base URL with a /. So if the
user was using `--baseurl rclone` then a request to
http://localhost/rclone would be redirected with a 308 response to
http://localhost/rclone/Fixes#4814
Before this change cgofuse and libatexit would race to see who could
unmount the file system with unpredicatable results. On Linux it could
report an error or not, depending.
This change checks to see if umount is beng called from a signal and
if so leaves the unmounting to cgofuse/libfuse.
See #4804
Create a full loop of documentation for rclone about, backends overview
and individual backend pages.
Discussion:
https://github.com/rclone/rclone/pull/4774 relates
Previously pull was requested, in part, under ref
https://github.com/rclone/rclone/pull/4801
Notes:
Introduce a tentative draft see-link format the end of sections to try
rather than lots of in-para links.
Update about.go incl link to list of backends not supporting about.
In list of backends not supporting about, include link to about command
reference.
I appreciate there may be decisions to make going forward about whether
command links should be code formatted, and using proper pretty url
links, but I have fudged that for now.
Update backend pages that do not support about with wording used
previously for ftp - it is in passive voice but I can live with it. (my
own wording and fault). The note is applied to a limitations section. If
one does not already exist it is created (even if there are other
limitations with their own sections)
This is done by making fs.Config private and attaching it to the
context instead.
The Config should be obtained with fs.GetConfig and fs.AddConfig
should be used to get a new mutable config that can be changed.
This shouldn't be read as encouraging the use of math/rand instead of
crypto/rand in security sensitive contexts, rather as a safer default
if that does happen by accident.
This caches all the objects returned from the List call. This makes
opening them much quicker so speeds up prune and restores. It also
uses fewer transactions. It can be disabled with
`--cache-objects=false`.
This was discovered when using the B2 backend when the budget was
being blown on list object calls which can avoided with a bit of
caching.
For typical 1 million file backup for a latop or server this will only
use a small amount more memory.
This adds a context.Context parameter to NewFs and related calls.
This is necessary as part of reading config from the context -
backends need to be able to read the global config.
It turns out that NFS calls mknod in FUSE even though we have create
defined. This was causing EIO errors when creating files.
This patch fixes it by implementing mknod. The way it is implemented
means that to write to an NFS file system you'll need --vfs-cache-mode
writes.
Before this change
RCLONE_DRIVE_CHUNK_SIZE=111M rclone help flags | grep drive-chunk-size
Would show the default value, not the setting of RCLONE_DRIVE_CHUNK_SIZE
as the non backend flags do.
This change makes it work as expected by setting the default of the
option to the environment variable.
Fixes#4659
Adds a flag, --progress-terminal-title, that when used with --progress,
will print the string `ETA: %s` to the terminal title.
This also adds WriteTerminalTitle to lib/terminal
This was accidentally removed when refactoring check and cryptcheck in
8b6f2bbb4b check,cryptcheck: add reporting of filenames for same/missing/changed #3264
`rclone obscure` currently only accepts a command line argument of `password` to generate
an obfuscated password. This is an issue since generating obfuscated passwords programatically
requires sending the plain text password as a shell argument, which can cause problems if the
password contains shell characters, or if the password is from an untrusted source.
This patch opens up STDIN which will allow developers to open the STDIN source and print a password
directly to `rclone obscure`, which can increase safety and convenince.
This is preparation for getting the Accounting to check the context,
buf first we need to get it in place. Since this is one of those
changes that makes lots of noise, this is in a seperate commit.
Before this change if the user supplied `-o uid=XXX` then rclone would
write `-o uid=-1 -o uid=XXX` so duplicating the uid value.
After this change rclone doesn't write the default `-1` version.
This fix affects `uid` and `gid`.
See: https://forum.rclone.org/t/issue-with-rclone-mount-and-resilio-sync/14730/27
This patch enables rclone to be used as a library from within restic
- exposes NewServer
- exposes Server
- implements http.RoundTripper
Co-authored-by: Jack Deng <jackdeng@gmail.com>
Before this change when reading directories we would use the directory
handle and the Readdir(-1) call on the directory handle. This worked
fine for the first read, but if the directory was read again on the
same handle Readdir(-1) returns nothing (as per its design).
It turns out that macOS leaves the directory handle open and just
re-reads the data from it, so this problem causes directories to start
out full then subsequently appear empty.
macOS/OSXFUSE is passing an offset of 0 to the Readdir call telling
rclone to seek in the directory, but we've told FUSE that we can't
seek by always returning ofst=0 in the fill function.
This fix works around the problem by reading the directory from the
path each time, ignoring the actual handle. This should be no less
efficient.
We will return an ESPIPE if offset is ever non 0.
There are possible corner cases reading deleted directories which this
ignores.
This uses the refactored goftp library which doesn't include the minio
driver. This reduces the binary size by 1.5MB
See: https://gitea.com/goftp/server/pulls/120
It is a source of confusion for users that `rclone mkdir` on a remote
which can't have empty directories such as s3/b2 does nothing.
This emits a warning at NOTICE level if the user tries to mkdir a
directory not at the root for a remote which can't have empty
directories.
See: https://forum.rclone.org/t/mkdir-on-b2-consider-adding-some-output/17689
- Use Driver.CheckPasswd instead of server.CheckPasswd
- Make server.CheckPasswd return an error
- Remove awful findID to find parent function hack
- Remove Driver.Init as it is no longer called
- Fix backwards incompatible PublicIp -> PublicIP change
See: https://gitea.com/goftp/server/issues/117
Otherwise, we get en dashes in the man page, making args more difficult
to copy/paste to a command line.
Before:
Use –addr to specify ...
After:
Use --addr to specify ...
This adds expire and unlink fields to the PublicLink interface.
This fixes up the affected backends and removes unlink parameters
where they are present.
This limit was previously 4k set in 59026c4761 however leaf
names above 1k now produce an IO error.
WinFSP seems to have its own method for dropping too long file names
above 255 long.
When wrapping a backend that supports Server Side Copy (e.g. `b2`, `s3`)
and configuring the `tmp_upload_path` option, the `cache` backend would
erroneously report that Server Side Copy/Move was not supported, causing
operations such as file moves to fail. This change fixes this issue
under these circumstances such that Server Side Copy will now be used
when the wrapped backend supports it.
Fixes#3206
Before this change there was some ambiguity about whether passwords
were obscured on not passing them into config create or config update.
This change adds the --obscure and --no-obscure flags to make the
intent clear.
It also updates the remote control and the tests.
Fixes#3728
This includes a new directory listing template which was originally
from the Caddy project (used with permission and copyright attribution).
This is used whenever we serve directory listings so `rclone serve
http`, `rclone serve webdav` and `rclone rcd --rc-serve`
This also modifies the tests so they work with the original template which
is easier to debug.
Before this change Windows would read a directory then immedately stat
every item in the directory.
After this change we return the stat information along with the
directory which stops so many callbacks.
Before this change, the current working directory could disappear
according to the Linux kernel.
This was caused by mount returning different nodes with the same
information in.
This change uses vfs.Node.SetSys to cache the information so we always
return the same node.
Before this change if you specified --hash MD5 in rclone lsf it would
calculate all the hashes and just return the MD5 hash which was very
slow on the local backend.
Likewise specifying --hash on rclone lsjson was equally slow.
This change introduces the --hash-type flag (and corresponding
internal parameter) so that the hashes required can be selected in
lsjson.
This is used internally in lsf when the --hash parameter is selected
to speed up the hashing by only hashing with the one hash specified.
Fixes#4181
These commands are for implementing backend specific
functionality. They have documentation which is placed automatically
into the backend doc.
There is a simple test for the feature in the backend tests.
The tests are now run for the mount commands and for the plain VFS.
This makes the tests much easier to debug when running with a VFS than
through a mount.
This allows rclone to exit with a non-zero return code if no files are
transferred. This is useful when calling rclone as part of a workflow/script
pipeline as it allows the end user to stop processing if no files have been
transferred.
NB: Enabling this option will return in rclone exiting non-zero if there are no
transfers. Depending on how your're currently using rclone in your scripts,
this may break existing setups!
--files-from parses input files by ignoring comments starting with # and ;
and stripping whitespace from start and end of strings.
The --files-from-raw flag was added that reads every line from the file ignoring
comment characters and not stripping whitespace while maintaining
backwards compatibility.
Fixes#3762
Basically, solving #3541 with a different approach - bringing in
the upstream upnpav module, and changing ChildCount from int to a
*int to avoid childCount="0" in the XML output when that value is
simply unknown.
Current approach is leading to some recursion issues and according
to the DLNA spec it shouldn't be necessary, anyway.
Before this changed we unconditionally fetched the MimeType. On Some
backends like s3 and swift this takes an extra transaction which meant
that `lsf` on those backends was needlessly slow.
This adds an internal option so `lsf` can declare whether it wants
MimeTypes or not depending on whether the user asked for them and an
external flag `--no-mimetype` for `lsjson`.
See: https://forum.rclone.org/t/reliably-setup-incremental-updates/14006/8
Unfortunately bcrypt only hashes the first 72 bytes of a given input
which meant that using it on ssh keys which are longer than 72 bytes
was incorrect.
This swaps over to using sha256 which should be adequate for the
purpose of protecting in memory passwords where the unencrypted
password is likely in memory too.
The failure is this which is not reproducable locally, only on the CI
servers.
--- FAIL: TestMount/CacheMode=minimal/TestWriteFileOverwrite (1.01s)
fs.go:351:
Error Trace: fs.go:351
write.go:65
Error: Received unexpected error:
open E:testwrite: The request could not be performed because of an I/O device error.
Test: TestMount/CacheMode=minimal/TestWriteFileOverwrite
The corresponding ERROR from the log is this:
ERROR : IO error: truncate C:\Users\runneradmin\AppData\Local\rclone\vfs\local\C\Users\RUNNER~1\AppData\Local\Temp\rclone298719627\testwrite: Access is denied.
Instead of using ioutil.WriteFile this fix uses an equivalent based on
rclone's lib/file which doesn't set the exclusive flag on
Windows. This allows files to be deleted that are open. It also
deletes existing files if an error is received and retries.
For few commands, RClone counts a error multiple times. This was fixed by
creating a new error type which keeps a flag to remember if the error has
already been counted or not. The CountError function now wraps the original
error eith the above new error type and returns it.
Before this change the race tests were taking too long. The bcrypt
function went from about 20ms to 1s under the race detector and this
is called for every transaction on webdav.
This change reduces the bcrypt strength so it takes 1ms non race so
the race tests pass and still has adequate security for in memory only
storage.
On google fs (drive, google photos, and google cloud storage), if
headless is selected, do not open browser.
This also supplies a new option "auth-no-open-browser" for authorize
if the user does not want it.
This should fix#3323.
Before this change `rclone mount` would give this error on FreeBSD
mount helper error: mount_fusefs: -o timeout=: option not supported
Because the default value for FreeBSD was set to 15m for
--daemon-timeout and that FreeBSD does not support the timeout option.
This change sets the default for --daemon-timeout to 0 on FreeBSD
which fixes the problem.
Fixes#3610
Before this change the sftp handler returned a nil error for unknown
operations which meant the server crashed when one was encountered.
In particular the "Readlink" operations was causing problems.
After this change the handler returns ErrSshFxOpUnsupported which
signals to the remote end that we don't support that operation.
See: https://forum.rclone.org/t/rclone-serve-sftp-not-working-in-windows/12209
If a file handle is duplicated with dup() and the duplicate handle is
flushed, rclone will go ahead and close the file, making the original
file handle stale. This change removes the close() call from Flush() and
replaces it with FlushWrites() so that the file only gets closed when
Release() is called. The new FlushWrites method takes care of actually
writing the file back to the underlying storage.
Fixes#3381
Seems to be some corner cases that are not being handled, so taking a different
approach that should be a little more robust.
Also, changing resources to be served under a subpath: We've been serving
media at /res?path=%2Fdir%2Ffilename.mp4; change that to be just /r/dir/filename.mp4.
It's cleaner, easier to reason about, and a necessary first step towards just
serving the resources via httplib anyway.
This problem was introduced in "mount: allow files of unkown size to
be read properly" 0baafb158f by failure to check that the
DirEntry was nil or not.
Allows for filename.srt, filename.en.srt, etc., to be automatically associated with video.mp4 (or whatever) when playing over dlna.
This is the "modern" method, which I've verified to work on VLC and in LG webOS 2. There is a vendor specific mechanism for Samsung that I havn't been able to get working on my F series.
Also made some minor corrections to logging and container IDs.
Before this change, files of unknown size (eg Google Docs) would
appear in file listings with 0 size and would only allow 0 bytes to be
read.
This change sets the direct_io flag in the FUSE return which bypasses
the cache for these files. This means that they can be read properly.
This is compatible with some, but not all applications.
This detects the presence of a VT100 terminal by using the TERM
environment variable and switches to using VT100 codes directly under
windows if it is found.
This makes --progress work correctly with git bash.
Before this change it was possible to make a remote with an invalid
name in the config file, either manually or with `rclone config
create` (but not with `rclone config`).
When this remote was used, because it was invalid, rclone would
presume this remote name was a local directory for a very suprising
user experience!
This change checks remote names more carefully and returns errors
- when the user tries to use an invalid remote name on the command line
- when an invalid remote name is used in `rclone config create/update/password`
- when the user tries to enter an invalid remote name in `rclone config`
This does not prevent the user entering a remote name with invalid
characters in the config manually, but such a remote will fail
immediately when it is used on the command line.
A workaround for #3489. Code in `__rclone_custom_func` relies on process substitutions `<(...)` to preserve changes of variables within `while` bodies, which is not supported in the posix mode.
Add a minimal number of mime types to augment go's built in types
for environments which don't have access to a mime.types file (eg
Termux on android)
Fixes#3475
Before this fix serve dlna was only using the built in database of
mime types to look up the mime types of files. On Android (and
possibly other systems) this is very small.
The symptoms of this problem was serve dlna only listing images and
not videos.
After this fix we use the backend's idea of the mime type if possible
which will be more accurate.
Fixes#3475
Before this change rclone marked files opened for write without VFS
cache with the non seekable flag.
This caused problems with rclone mount layerd with mergerfs.
This change removes the hint and lets rclone do all the checking for
seekability.
Before this change `rclone rc --loopback` would give the error "bad
JSON".
This was because the output of the `rc/list` command was not serialzed
through JSON.
This serializes it through JSON and fixes that (and probably other)
command.
rc: WebGUI should check for new update only when rc-web-gui-update is specified or not already downloaded.
rc: change permission to 0755 instead of 755 to prevent unexpected behaviour.
Before this change, using -P occasionally deadlocked on the progress
mutex and the stats mutex since they call each other.
This is fixed by shortening the locking window in the progress routine
so as not to include the stats calculation.
This was factored from fstest as we were including the testing
enviroment into the main binary because of it.
This was causing opening the browser to fail because of 8243ff8bc8.
This adds experimental support for web gui integration so that rclone can fetch and run a web based GUI using the --rc-web-ui and related flags.
It downloads and caches a webui zip file which it then unpacks and opens in the browser.
Introduce stats groups that will isolate accounting for logically
different transferring operations. That way multiple accounting
operations can be done in parallel without interfering with each other
stats.
Using groups is optional. There is dedicated global stats that will be
used by default if no group is specified. This is operating mode for CLI
usage which is just fire and forget operation.
For running rclone as rc http server each request will create it's own
group. Also there is an option to specify your own group.
This is done to make clear ownership over accounting object and prepare
for removing global stats object.
Stats elapsed time calculation has been altered to account for actual
transfer time instead of stats creation time.
This was started by Fionera, finished off by Laura with fixes and more
docs from Nick.
Co-authored-by: Fionera <fionera@fionera.de>
Co-authored-by: Nick Craig-Wood <nick@craig-wood.com>